Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : Iflow
Model Number : EMF-100-1
Certification : ISO9001, CE
Place of Origin : China
MOQ : 1
Price : negotiable
Payment Terms : T/T, L/C, D/P, Western Union
Supply Ability : 1000 sets per month
Delivery Time : 2-4 weeks
Packaging Details : carton / box
Product name : flow meter for sewage
Flow sensor : remote transmitter
Pressure rating : PN16, PN25, PN40 Mpa
Temperature : ±(0.3 + 0.05 * T)K; ΔT = T ± 0.1K
Electrode : 316L / Hasteloy-C / Ti / Ta / Pt100
Accuracy : 0.25% , 0.5%
Communication : BACNET/Modbus/RS485/4-20 mA
Pipe connect : Flange
Wastewater flow meter, magnetic flow transmitter, DN15-1200, Rubber liner
General description
The magnatice flow meter diameter from 1" to 48 " (Larger size available upon request). The EMF has no parts to obstruct flow resulting in no pressure loss and the 0.5% accuracy is not affected by temperature, pressure, viscosity, density or flow profile. With no moving parts, practically no maintenance is required. The chloroprene rubber sensor liner is suitable for liquid temperatures from -13 to 176°F and is compatible with most water-based fluids and many chemicals. Contact us for additional chemical compatibility information.
Applications:
Irrigation, clean water, paper pulp, slurry, sewage, waste water, HVAC/R system monitoring, residential water meter, industrial & commercial water utilities
Technical data:
1. Diameter: DN15 - DN1200
2. Pressure rating: PN10/PN16/PN25/PN40
3. Media temperature: 0-80 C (Rubber), 0-120 C (PTFE)
4. Environment temperature: 0 - 60 C
5. Protection: IP68 (flow sensor)
6. Explosion proof: EXID
Parameters
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Measure Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
![]() |