Brand Name : Iflow

Model Number : YE-F

Certification : ISO9001, CE

Place of Origin : China

MOQ : negotiable

Price : negotiable

Payment Terms : T/T, L/C

Supply Ability : 2200000 units per year

Delivery Time : 4-6 weeks

Packaging Details : wooden case pluse pallet

Type : Electromagnetic flow meter YF

Port size : DN100

Connect port : flange

Electrode : 316L / Hasteeloy-C / Ti / Ta / Pt100

Measure : flow and heat

Protection : IP68

Accuracy : 0.25% , 0.5%

Power supply : 85 - 265V AC / 8-36V DC

Contact Now

ElectroMagnetic Flow Meter, electrode: 316L, housing material: 316L, PTFE liner for WTP waste water discharge

Description

The electromagnetic flow meters use Faraday’s Law of Electromagnetic Induction to determine the flow of liquid in a pipe. In a magnetic flowmeter, a magnetic field is generated and channeled into the liquid flowing through the pipe. Following Faraday’s Law, flow of a conductive liquid through the magnetic field will cause a voltage signal to be sensed by electrodes located on the flow tube walls. When the fluid moves faster, more voltage is generated. Faraday’s Law states that the voltage generated is proportional to the movement of the flowing liquid. The electronic transmitter processes the voltage signal to determine liquid flow.
It’s externally powered with 100-240VAC or 24 VDC. Low power requirements also make it ideal for solar

and comparable power sources. Rate and total indication is standard, as is a solid state pulse / frequency /

4-20mA output, that allows connection to a data logger.
The display housing can be either integrated or remote. A shielded power/pulse output cable with DIN connection

is included with the meter.

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

Grounding

From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.

Technical data

Product name Electromagnetic flowmeter
Product type Local|compact display Remote display Signal converter
Model IYF-E IYF-F IRT
Pipe Diameter (mm) DN10-DN2000
Power supply 100-240 VAC / 18-36 VDC
Accuracy + 0.5% + 0.5% + 0.5%
Power consumption <6w <6w <6w
Enclosure rating IP65 IP68 IP65
Liquid temperature -25-120℃ -25-120℃ -25-120℃
Ambient temperature -25-50℃ -25-50℃ -25-50℃
Relative humidity 10-90% 10-90% 10-90%
Meter ratio 1:100 1:100 1:100
Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

Features

  • Virtually no pressure loss
  • Suitable to meter for wide range of conductive liquid media
  • No Moving Parts
  • Flanges port connection
  • RS485 Standard
  • Suitable for Pipes diameter p to 2000 mm
  • Large meter ratio
  • High Accuracy
  • 4 to 20 mA / Frequency / Pulse output

Mounting notice

Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter

Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter

Model selection

Applicable metering liquid:

  • Conductive liquid media, conductivity > 5 µS/ cm
  • Various Conductive aqueous solutions, water solutions, acid & caustics
  • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
    water, effluent, fibrous, viscous, paper mill, food & beverage

Non-applicable metering medial

  • Industrial gas, compressed air, steam, or liquid with large content of gas
  • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
    water, clean gas, etc.

Notice on the selection of local type and remote type:

Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:

  • Ambient temperature or converter display sunshine temperature is over 60 ℃
  • High humidity or corrosive air existed
  • Serious pipe vibration
  • Magnetic meter need be suspended or submersible, uneasily read out
  • Other abrasive condition
I Model
YF Electromagnetic flowmeter
TF Turbine
VF Votex
LX Vane wheel
T Ultrasonic
E/F display mode E: compact/local display, F: remote display
Pipe Dia Type (mm)
xxxx

15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

500, 600, 800, 1000

Code Accuracy
1 + 0.5% FS
2 + 1.0% FS
3 + 0.2% FS
Code Type
N Converter: 12 / 24 VDC, pulse output
A Transmitter: 24VDC, 4-20mA outpt
B Intelligent, Lion battery, no local display
G Smart, local display, 4-20mA output
C1 Smart, local display, RS485
C2 Smart, local display, HART
Code Type
S Carbon steel housing
L Stainless steel housing
G High pressure housing
HL 316L electrode
HTi Titanium electrode
HTa Tantlum electrode
HC Hastelloy-C electrode
L1 Liquid media
L2 Gas media
P Pressure compensation
T Temperature compensation
PT Pressure&Temp. Compensation
F PTFE liner
X Rubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

Pipe Diameter, flow volume and product dimension

Dia Flow volume (m3/h) Product dimension (mm)
(mm) Normal Min Max L D H H1
15 1.5 0.06 9.5 150 95 272 254
20 2.5 0.11 16.9 105 277 254
25 3.5 0.18 26.5 115 283 254
32 6 0.29 43.6 140 297 270
40 10 0.45 67.8 150 307 280
50 15 0.71 106.0 200 165 318 294
65 25 1.19 179.1 185 337 313
80 40 1.81 271.4 200 352 326
100 60 2.83 424.1 250 220 371 344
125 100 4.42 665 250 401 372
150 135 6.36 954 300 285 431 403
200 250 11.3 1696 350 340 486 460
250 375 17.66 2650 400 395 547 511
300 540 25.43 3817 450 445 597 565
350 735 34.62 5195 505 657 620
400 960 45.22 6785 500 565 717 675
450 1200 57.23 8588 550 615 757 727
500 1500 70 10602 600 670 817 782
600 2160 100 15268 780 917 782
700 2950 138 20781 700 895 1027 1068
800 3850 180 27100 800 1015 1137 1157

Industrial applications

Chemical Food & beverage Paper mill
Metallurgy Environment protection Hydraulic
Mining Stainless Petroleum
Pharmacy Air conditioner Effluent treatment plant
Seawater desalination Pharmacy Water treatment

Competitive advantage

  • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
  • Strict process control
  • Advanced calibration equipment
  • Engineer team

Process control

Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter

Calibration equipment

Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter


Product Tags:

electronic water meter

      

magnetic inductive flow meter

      
China Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter wholesale

Bacnet Signal Output External Flow Meter , 25-600mm ISO9001 Magnetic Flowmeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai I Fluid Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0